Stop changing oil. Start measuring it.

Oil analysis turns a maintenance calendar into a decision: top up, filter, flush, or plan the intervention while there is still a plan to make. Three packages, standard methods, results written against the limit you are being judged by.

Why it pays

A bottle of oil is the cheapest inspection you will ever buy.

A gearbox that will eventually need a crane, a nacelle crew and a new gear set gives warning first — in iron, in water, in acid number, in viscosity. Every one of those warnings is measurable months before it becomes a borescope finding.

Predictive maintenance is not a dashboard. It is a trend line, a limit, and an engineer willing to write down what they think is happening. That is what comes back with our reports.

What you get
  • A report against OEM limits, not a bare table of numbers.
  • Trend commentary once two or more samples exist.
  • Automatic escalation to ferrography on high iron, copper or PQ.
  • Sampling guidance for gearbox, hydraulic and bearing points.

Packages

Three tiers, one laboratory.

Choose by component, not by budget. A gearbox sample without water and TAN tells you almost nothing; a grease sample with the wrong test wastes a bearing inspection opportunity.

A

Gear oil

The routine gearbox package: condition, contamination and wear in one report.

  • Appearance — visual
  • Kinematic viscosity @ 40 °C · D445
  • Water content · D6304
  • Total acid number · D664 / D974
  • Elemental wear metals · D5185
B

Gearbox & hydraulic

Package A plus cleanliness, for pitch, yaw and brake hydraulics.

  • Everything in Package A
  • ISO 4406 cleanliness code · ISO 11500
  • Particle count, ≥4 / ≥6 / ≥14 µm
C

Grease

Main bearing, pitch bearing and generator bearing grease.

  • Appearance — visual
  • Elemental analysis · ASTM D7303
  • PQ index · ASTM D8184
  • Water · D6304 / D95 / GB/T 512
Parameter coverage by package
ParameterA · gear oilB · + hydraulicC · grease
Appearance✓✓✓
Kinematic viscosity @ 40 °C✓✓—
Water content✓✓✓
Total acid number✓✓—
Elemental wear metals✓✓✓
ISO 4406 cleanliness—✓—
PQ index——✓
Ferrography (optional)✓✓—

Ferrography

When the numbers say “open it”.

Analytical ferrography separates wear particles by size and shape, then tells you what is wearing: sliding wear from a gear flank, cutting wear from a damaged bearing surface, or oxide particles from overheating.

  • Automatic trigger — iron > 1000 ppm, copper > 200 ppm, or PQ index > 2000.
  • Orderable on any sample, by method SH/T 0573 or ASTM D7690.
  • Read by a human — the report names the likely component, not just the morphology.
Escalation thresholds
IndicatorTriggerAction
Iron (Fe)> 1000 ppmFerrography + trend review
Copper (Cu)> 200 ppmFerrography + bearing check
PQ index> 2000Ferrography + borescope planning

Thresholds follow the service specification. Your OEM limit takes precedence where it is stricter.

Sampling

Most bad results are bad samples.

We send bottles, labels and a written procedure. The rest is discipline: the same point, the same running state, the same position in the drain sequence, every time.

01

Agree the plan

Which components, which intervals, which limits. Gearbox quarterly, hydraulic twice a year, bearings on condition — whatever your OEM and your fleet history justify.

02

Take the sample

Live sample from a sampling valve or a drop tube into the sump, mid-drain, with the machine at operating temperature. Label, date, hours, component.

03

Ship and test

Bottles travel to the laboratory; methods are fixed and traceable. Results are reported against the limits agreed in step 1.

04

Close the loop

Every report ends in an action: no action, monitor, top up, filter, or plan an intervention. Nothing else counts as a result.

Questions

Practical answers.

How often should I sample a gearbox?

Every three, six or twelve months depending on fleet age and OEM guidance, plus one sample 500 hours after any oil change. Trending beats any single reading.

When is ferrography added?

Automatically when iron passes 1000 ppm, copper passes 200 ppm or PQ index passes 2000. It can also be ordered directly on any sample.

Can you test grease from a main bearing?

Yes — Package C covers main, pitch and generator bearings with elemental analysis, PQ index and water.

Do you test other brands of oil?

Yes. The laboratory tests the oil in the machine, whoever supplied it. If the result points to a change, we will say so in writing.